Event Code: 504
Message: Port module failure
Severity: Major
Explanation: A failure associated with a four-port hardware module has been detected. The amber Service Required LED is
illuminated on each of the module’s four contiguous ports.
Action: Perform data collection procedure for the switch using the EFC Manager, save the data file to the EFC Server Zip
drive. Return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists, replace
the switch.
Event Data: Byte 0 = Slot position
Byte 1 = Reason code
00 = Operator requested with debug command
02 = Initialization failure
03 = Hot plug/power up diagnostics failure acknowledgment
04 = Board ready timeout
05 = Read of module ID failed
06 = Statistical error threshold reached
07 = Communication with hardware is irregular or non-existent
Bytes 4 - 7 = Elapsed millisecond tick count
Bytes 8 - 11 = Reason code specific data #1 (Internally defined)
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔