B
B-26
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 302
Message: Third cooling fan propeller has failed
Severity: Major
Explanation: A third fan has failed. The fan has stopped or was removed. The remainder of the fans in the system are installed
and operational. If present, the LED on the associated fan module is turned off. The fan has either stopped or
was removed.
Action: Replace the fan module immediately.
Event Data: Byte 0 = Failed fan number (1-6).
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 303
Message: Fourth cooling fan propeller has failed
Severity: Major
Explanation: A fourth fan has failed. The fan has stopped or was removed. The remainder of the fans in the system are
installed and operational. If present, the LED on the associated fan module is turned off. The fan has either
stopped or was removed.
Action: Replace the fan module immediately.
Event Data: Byte 0 = Failed fan number (1-6).
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔