Event Code Tables
Event Code: 802
Message: Port module shutdown due to thermal violations
Severity: Major
Explanation: The Port Module has been marked failed and power has been removed from the board due to excessive heat.
This event follows an indication that the port module "hot" threshold level has been surpassed (event 801).
Action: Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 805
Message: High-temperature warning (SBAR module thermal sensor).
Severity: Major
Explanation: The thermal sensor associated with the SBAR module has detected that the "warm" temperature threshold level
has been surpassed.
Action: Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔