3
Maintenance Analysis Procedures
3-5
Diagnostics
505 Port module revision not supported. No action required.
506 Fibre Channel port failure. Go to MAP 0600.
507 Loopback diagnostics port failure. Go to MAP 0600.
508 Fibre Channel port anomaly detected. Go to MAP 0600.
510 SFP hot-insertion initiated. No action required.
512 SFP nonfatal error. Go to MAP 0600.
513 SFP hot-removal completed. No action required.
514 SFP failure. Go to MAP 0600.
581 Implicit incident. Go to MAP 0600.
582 Bit-error threshold exceeded. Go to MAP 0600.
583 Loss of signal or loss of synchronization. Go to MAP 0600.
584 Not operational primitive sequence (NOS) received. Go to MAP 0600.
585 Primitive sequence timeout. Go to MAP 0600.
586 Invalid primitive sequence received for link state. Go to MAP 0600.
602 SBAR module anomaly detected. No action required.
604 SBAR module failure. Go to MAP 0600.
605 SBAR module revision not supported. Go to MAP 0600.
800 High-temperature warning (port module thermal
sensor).
Go to MAP 0500.
801 Critically hot temperature warning (port module thermal
sensor).
Go to MAP 0500.
802 Port module shutdown due to thermal violations. Go to MAP 0500.
805 High-temperature warning (SBAR module thermal
sensor).
Go to MAP 0500.
806 Critically hot temperature warning (SBAR module
thermal sensor).
Go to MAP 0500.
807 SBAR module shutdown due to thermal violations. Go to MAP 0500.
Table 3-3 Event Codes versus Maintenance Action (continued)
Event
Code
Explanation Action