B
Power Supply Events (200 through 299)
B-23
Event Code Tables
Event Code: 206
Message: Power supply removed
Severity: Informational
Explanation: The indicated supply has been removed from the switch while system power was on. This event can only occur
when dual power supplies are installed. The other power supply automatically adjusts to assume the system full
load providing uninterrupted system power.
Action: Re-install an operational power supply.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 207
Message: Power supply installed
Severity: Informational
Explanation: A redundant power supply has been installed while system power was on and the switch was operational. Both
supplies automatically adjust to share the system load.
Action: No action required.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔