B
B-66
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 586
Message: Invalid primitive sequence received for current link state
Severity: Major
Explanation: The incident node has recognized either a Link-Reset (LR) or a Link-Reset_Response (LRR) Primitive Sequence
while in the Wait-for-OLS state (see FC-PH clauses 16.5.4.3).
Action: A Link-incident Record (LIR) is generated and sent to the host using the Link-Incident reporting procedure
defined in the T11/99-017v0 document. If, after fault isolation is performed by the host, it is determined that the
incident is because of a port failure, perform a data collection procedure for this switch using the EFC Manager,
and return the CD to McDATA for analysis.
Event Data: Byte 0 = Port number (00-3F)
Bytes 4-7 = Elapsed millisecond tick count
Bytes 8-11 = Port state indicators
0x00 = Active
0x01 = OLIB
0x05 = LR1
0x06 = LR2
0x07 = LR3
0x09 = LF2
0x0A = LF1
0x0C = OL1A
0x0D = OL1C
0x0E = OL2
0x0F = OL3
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔