McDATA 3232 Switch User Manual


 
B
B-60
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 513
Message: SFP optics hot-removal completed
Severity: Informational
Explanation: The hot removal of a Small Form Factor pluggable optics transceiver has been detected.
Action: No action required.
Event Data: Byte 0 = Port number (00-8F)
Bytes 4-7 = Elapsed millisecond tick count.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 514
Message: SFP optics failure
Severity: Major
Explanation: A Small Form Factor pluggable optics module failure has been detected by the system software.The amber LED
associated with this port is illuminated.
Action: Replace the Small Form Factor optics module with a working module of the same type. If the amber LED does
not extinguish when the new module is inserted, see the Port Failure event (506).
Event Data: Byte 00 = Port number (00-8F)
Byte 01 = Reason code
00 = Optics component has asserted its fail signal
Bytes 04-07 = Elapsed millisecond tick count
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔