A
Sphereon 3032/3232 Element Manager Messages
A-29
Messages
Message Switch clock alert mode must be cleared before enabling period
synchronization.
Description Clock alert mode is enabled through the Configure FICON
Management Server dialog box and user is attempting to enable
Periodic Date/Time Synchronization through the Configure Date and Time
dialog box.
Action Disable clock alert mode through the Configure FICON Management
Server dialog box.
Message System diagnostics cannot run. The Operational Status is invalid.
Description System diagnostics cannot run on switches with failed ports.
Action Replace failed ports.
T
Message The add firmware process has been aborted.
Description User has ended the add firmware process.
Action N/A. An informational message.
Message The data collection process failed.
Description An error occurred in the data collection process.
Action Contact support personnel.
Message The data collection process has been aborted.
Description User has ended the data collection process.
Action N/A. An informational message.