McDATA 3232 Switch User Manual


 
5
5-4
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
FRU Removal and Replacement
If an event code 513 does not appear in the log, go to MAP 0000:
Start MAP on page 3-6 to isolate the problem.
7. At the EFC Server’s Hardware View:
a. Ensure no alert symbols appear that indicate a failure (yellow
triangle or red diamond).
b. Click the port graphic representing the replacement SFP to
open the Port Properties dialog box. Verify that port
information (port number, port name, operational state, and
port technology) is correct.
If a problem is indicated, go to MAP 0000: Start MAP on page 3-6
to isolate the problem.
8. Restore communication to the port and set the port online as
directed by the customer (Unblock a Port on page 4-47).
9. Perform the data collection procedure (Collecting Maintenance
Data on page 4-36).
10. Clear the switch’s system error (ERR) LED:
If at the EFC Server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a FRU) to
open a pop-up menu.
b. Click Clear System Error Light.
If at a web browser connected to the SANpilot interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with the
Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
RRP: Power Supply
Use the following procedures to remove or replace a power supply
from the rear of the switch. No tools are required.
Removal
To remove a power supply: