4
4-18
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Repair Information
FRU List View
The FRU List View (Figure 4-10 on page 4-18) displays a list of all
switch FRUs. The information is useful to maintenance personnel for
fault isolation and repair verification.
Figure 4-10 FRU List View
To open the FRU List View from the Hardware View, click View and
select FRU List. The FRU List View contains the following columns:
• FRU - an acronym representing the FRU type. FRU acronyms
are:
— SFP - Small form factor pluggable (SFP) optical transceiver.
Chassis slots for SFPs inserted in a port are 0 through 31. The
SFPs are FRUs.
— PWR - power supply. Chassis slots for redundant power
supplies are 0 and 1. The power supplies are FRUs.
— FAN - cooling fan. Chassis slots for redundant fans are 0 (fan
FRU assembly) and 1 through 4 (cooling fans). The cooling
fans are FRUs.
— CTP - control processor (CTP) card. The chassis slot is 0. The
CTP card is not a FRU.