McDATA 3232 Switch User Manual


 
A
A-28
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Messages
Message SNMP trap address not defined.
Description An SNMP trap address must be defined if a community name is
defined.
Action Define an SNMP address.
Message Switch Binding was removed from attached devices that are also
participating in Port Binding. Please review the Port Binding
Configuration.
Description The device WWNs were removed from the director’s Switch
Membership List (SANtegrity Switch Binding feature), but you
should note that one or more of these devices still has security control
in port binding.
Action Verify that the security level for each device is as required by
reviewing the Bound WWN list in the Configure Ports dialog box.
Message Stop diagnostics failed. The test is already running.
Description Diagnostics for the port was not running and the Stop was selected on
the Port Diagnostics dialog box. Diagnostics quit for the port for some
reason, but the Stop button remains enabled.
Action Verify port operation. Retry diagnostics for port and select Stop from
the dialog box. If problem persists, contact your service
representative.
Message Stop diagnostics failed. The test was not running.
Description The action to stop diagnostics failed because the test was not running.
Action Informational message.