B
CMM Module Events (800 through 899)
B-73
Event Code Tables
CMM Module Events (800 through 899)
Event Code: 800
Message: High-temperature warning (Port module thermal sensor).
Severity: Major
Explanation: The thermal sensor associated with the port module has detected that the "warm" temperature threshold level
has been surpassed.
Action: Perform the data collection procedure for the switch using the EFC Manager, and return the CD to McDATA for
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 801
Message: Critically hot temperature warning (Port module thermal sensor)
Severity: Major
Explanation: The thermal sensor associated with the port module has detected that the "hot" temperature threshold level has
been surpassed.
Action: Perform the data collection procedure for this switch using the EFC Manager, and return the CD to McDATA for
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔