User Guide for Polycom® RMX™ 500 and Polycom® RMX™1000 Systems
(Conference on Ports)
15-7
5 Click OK.
6 When the information on the MCU device is backed up, click OK in the
popup message box, and then click Restart Now.
When the two RMX devices with hot standby configured are restarted, the
device started first will become a master device, and the other one will be
used as a slave device.
Log into the Web configuration page for the master device and you can view
the information for the master/slave device in the list of hot standby
machines. Click the button to manually switch your master/slave
device.
During the period when the hot standby function is enabled, you cannot upgrade your
devices.
Hardware Monitoring
In the Hardware Monitoring area, the Status column lists the current working
status of a unit, such as the usage, fan speed and temperature. If the status of
a hardware unit goes beyond the normal range, the "System Alerts" area
blinks red and displays an alert message. The table below shows the normal
operating range of each hardware unit.
Normal Range of the Hardware Status
Unit Normal Range
CPU 0-67 Celsius degree
Motherboard 0-65 Celsius degree
Memory 0-95 Celsius degree
Fan Speed 200-8000 RPM