The table below explains the detailed meanings of these parameters.
Parameter Description for New Meeting RoomGeneral
Parameter
Description
Meeting Room
Name
Set a unique name to identify the meeting room. When a
meeting room is created, the system will automatically generate
a unique name for it.
Profile
Select the profile to be used for this conference from the
drop-down list. The lower part of this option displays the major
parameter values defined for the profile:
Line Rate: the maximum bandwidth used by a participant in a
conference;
Minimum Number of Reserved Resources/Maximum
Number of Available Resources: the minimum/maximum
number of video participants to join a conference. Automatic
indicates that the number of video participants is determined
according to the available resource of the RMX.
The conference profile defines the basic parameters of
conference scheduling, such as the bandwidth, encryption, and
video quality. For more information on conference profiles, see
Conference Profiles. When a conference is created, the system
selects the default profile by default.
Conference
Duration
Specify the conference duration in the range of 0-24 hours. The
input format is H:M and the default value is 8:0, namely, 8
hours.
Conference ID
When a meeting room is created, the system automatically
allocates a conference ID. You can also set a unique
conference ID on the device. To directly dial into the
conference, the participant must know its ID.
Conference
Password
Enter the conference password. To connect to this conference,
the participant must enter this password. If this parameter is
empty, it means the conference has no password.