Toshiba VF-S9 Power Supply User Manual


 
E6580757
F-51
6
[Parameter setting]
Title Function Adjustment range Default setting
Prohibition of change of
parameter settings
0: Permitted
( , cannot be modified during
operation)
1: Prohibited
2: Permitted
( , can be modified during op-
eration)
0
Resetting method
Only the parameter is designed so that its setting can be modified even if " " (prohibited) is se-
lected.
6.16.2 Changing the display unit to A/V/min
-1
: Unit selection
: Free unit selection
Function
These parameters are used to change the unit of monitor display.
% A (ampere)/V (volt)
Frequency Motor speed or load speed
Parameter setting
Title Function Adjustment range Default setting
Unit selection
0: No change
1: % A (ampere)/V (volt)
2: Free unit selection enabled ( )
3: % A (ampere)/V (volt)
Free unit selection enabled ( )
0
Free unit selection
0.01 200.0
1.00
An example of setting for changing voltage/current percentage display to V/A unit
display
Set to either " " or " ".
During the operation of the VFS9-2037PM (rated current: 17.5A) at the rated load (100% load), units are dis-
played as follows: