Toshiba VF-S9 Power Supply User Manual


 
E6580757
K-8
11
Default settings by inverter rating
Inverter model Torque boost Slip frequency Motor primary
constant
Motor secon-
dary constant
Motor excitation
constant
/
VFS9S-2002PL 6.0% 3.0Hz 33 35 35
VFS9S-2004PL 6.0% 3.0Hz 36 39 39
VFS9S-2007PL 6.0% 3.0Hz 36 28 44
VFS9S-2015PL 6.0% 2.7Hz 26 16 42
VFS9S-2022PL 5.0% 2.7Hz 28 17 44
VFS9-2002PM 6.0% 3.0Hz 33 35 35
VFS9-2004PM 6.0% 3.0Hz 36 39 39
VFS9-2007PM 6.0% 3.0Hz 36 28 44
VFS9-2015PM 6.0% 2.7Hz 26 16 42
VFS9-2022PM 5.0% 2.7Hz 28 17 44
VFS9-2037PM 5.0% 2.7Hz 27 15 37
VFS9-2055PL 4.0% 2.0Hz 17 11 37
VFS9-2075PL 3.0% 2.0Hz 13 12 36
VFS9-2110PM 2.0% 1.7Hz 13 11 42
VFS9-2150PM 2.0% 1.7Hz 9 11 37
VFS9-4007PL 6.0% 3.0Hz 27 15 38
VFS9-4015PL 6.0% 2.7Hz 28 16 39
VFS9-4022PL 5.0% 2.7Hz 28 39 39
VFS9-4037PL 5.0% 2.7Hz 28 26 41
VFS9-4055PL 4.0% 2.0Hz 17 11 43
VFS9-4075PL 3.0% 2.0Hz 13 12 37
VFS9-4110PL 2.0% 1.7Hz 13 11 42
VFS9-4150PL 2.0% 1.7Hz 9 11 37
Table of input terminal functions (1/3)
Function
No.
Code Function Action
0 - No function is assigned Disabled
1 ST Standby terminal When is set at - ON:
Gate on, OFF: Gate off (free-run)
When is set at - OFF:
Gate on, ON: Gate off (free-run)
2 F Forward-run command ON: Forward run
OFF: Slowdown stop
3 R Reverse-run command ON: Reverse run
OFF: Slowdown stop (Reverse run has priority.)
4 JOG Jog run command ON: Jog run, OFF: Jog run canceled
5 AD2 Acceleration/deceleration 2 pattern selection ON: Acceleration/deceleration 2, OFF: Accelera-
tion/deceleration 1
6 SS1 Preset-speed command 1
7 SS2 Preset-speed command 2
8 SS3 Preset-speed command 3
9 SS4 Preset-speed command 4
Selection of 15-speed with SS1 to SS4 (4 bits)
10 RST Reset command
ON OFF: Trip reset
11 EXT Trip stop command from external input device ON: trip stop
12 PNL/TB Operation panel/terminal board switching ON: Forced switching from panel control (Internal
potentiometer)to terminal board control
13 DB DC braking command ON: DC braking
14 PI Prohibition of PI control ON: PI control prohibited
OFF: PI control permitted
15 PWENE Permission of parameter editing ON: Parameter editing permitted, OFF: Parameter
editing prohibited