E6580757
E-23
5
2) Preset-speed frequency setting
Set the speed (frequency) of the number of steps necessary.
Setting from speed 1 to speed 7
Title Function Adjustment range Default setting
∼
or
~
Preset-speed operation frequencies
1~7
∼ (Hz)
0.0
Setting from speed 8 to speed 15
Title Function Adjustment range Default setting
∼
Preset-speed frequencies 8~15
∼ (Hz)
0.0
Examples of preset-speed contact input signals (JP301 set to sink logic)
O: ON -: OFF (Speed commands other than preset-speed commands are valid when all are OFF)
Preset-speed
Terminal
123456789101112131415
S1-CC { - { - { - { - { - { - { - {
S2-CC - {{ --{{ --{{ --{{
S3-CC---{{{{ ----{{{{
RST-CC-------{{{{{{{{
✩ Terminal functions are as follows.
Terminal S1............. Input terminal function selection 4 (S1) =6 (SS1)
Terminal S2............. Input terminal function selection 5 (S2) =7 (SS2)
Terminal S3............. Input terminal function selection 6 (S3)
=8 (SS3)
Terminal RST..........Input terminal function selection 3 (RST) =9 (SS4)
✩ SS4 is not allocated to standard default setting. Use the input terminal function selection to allocate SS4
an idle terminal. In the above example the RST terminal is used for SS4.
Example of a connection diagram (JP301 set to sink logic)
CC
RST
S2
S3
S1
F (Forward run)
R (Reverse run)
Forward
Preset-speed 1
Reverse
Preset-speed 4
Preset-speed 3
Preset-speed 2
VF-S9
CC
S1
S2
RST
S3