Toshiba VF-S9 Power Supply User Manual


 
E6580757
K-2
11
Title Communication
No.
Function Unit Minimum
setting unit
Adjustment range Default
setting
User
setting
Reference
0008 Forward/reverse
run selection
(Operation panel)
- - 0: Forward run
1: Reverse run
05.8
0009 Acceleration
time 1
s 0.1 0.1-3600 10.0 5.1
0010 Deceleration
time 1
s 0.1 0.1-3600 10.0 5.1
0011 Maximum
frequency
Hz 0.1 30.0-400 80.0 5.9
0012 Upper limit
frequency
Hz 0.1 0.5- *1 5.10
00013 lower limit
frequency
Hz 0.1 0.0- 0.0 5.10
0014
Base frequency 1 Hz 0.1 25-400 60.0 *1 5.11
0015 V/F control mode
selection
- - 0: V/F constant
1: Variable torque
2: Automatic torque boost
3: Sensorless Vector control
4: Automatic energy-saving
05.12
0016 Torque boost %/(V) 0.1 0.0-30.0 *2 5.13
0041 Motor
electronic-thermal
protection level 1
%/(A) 1 10-100 100 5.14
Setting type Overload protection OL stall
0
{
×
1
{{
2
××
3
Standard
motor
×
{
4 {
×
5
{{
6
××
0017 Electronic-thermal
protection
characteristic
selection *4
--
7
VF motor
(special
motor)
×
{
05.14
to
0018
to
0024
Preset-speed
operation
frequencies 1 to 7
Hz 0.1 - 0.0 5.15
____ - Extended
parameter
--- --4.1
- Automatic edit
function
--- --4.1
*4 : { : valid, × : invalid
11.3 Extended parameters
Input/output parameters
Title Communication
No.
Function Unit Minimum
setting unit
Adjustment range Default
setting
User
setting
Reference
0100 Low-speed signal
output frequency
Hz 0.1 0.0- 0.0 6.1.1
0101 Speed reach
setting frequency
Hz 0.1 0.0- 0.0 6.1.3
0102 Speed reach
detection band
Hz 0.1 0.0- 2.5 6.1.2
0103 ST signal
selection
- - 0: Stand by on when ST is on
1: Stand by always on
2: Interlocked with F/R
3: Stand by on when ST is off
1 6.2.1
0104 RST signal
selection
- - 0: Default
1: Activated by turning RST off
0 6.2.2