Toshiba VF-S9 Power Supply User Manual


 
E6580757
J-6
10
No. Device Function and purpose
(11)
Parameter writer Use this unit for batch read, batch copy, and batch writing of setting parameters.
(Model: PWU001Z)
(12)
Extension panel Extended operation panel kit provided with LED indication section, RUN/STOP key,
UP/DOWN key, Monitor key, and Enter key.
(Model: RKP001Z)
(13)
RS485 communication
converter unit
Use to connect a personal computer for data communication with up to 64 units.
(Model: RS4001Z)
(14)
RS232C communication
converter unit
Use to connect a personal computer for data communication.
(Model: RS2001Z)
(10)
Remote panel Provided with built-in frequency indicator, frequency setting device, and RUN-STOP (for-
ward/reverse) switch.
(Model: CBVR-7B1)
(15)
Application control unit AP Series is available to enable various types of application control functions when com-
bined with an inverter. Contact your Toshiba representative for further information.
Table for selection of optional external devices
Radio noise
reduction filter
Voltage
class
Capacity of
applicable
motor
Inverter model
Input AC
reactor
(Note 2)
DC
reactor
(Note 2)
High-
attenuation
type
Core type
(See Note 1.)
Braking
resistor
Motor-end
surge voltage
suppression
filter
Conduit
pipe kit
Foot-mounted type
noise reduction filter
DIN
adapter
0.2 VFS9S-2002PL PFL-2002S DCLS-2002 - RC5078 PBR-2007 - NEM010Z EMFS2010AZ DIN001Z
0.4 VFS9S-2004PL PFL-2005S DCL-2007 - RC5078 PBR-2007 - NEM010Z EMFS2010AZ DIN001Z
0.75 VFS9S-2007PL PFL-2011S DCL-2022 - RC5078 PBR-2007 - NEM010Z EMFS2010AZ DIN001Z
1.5 VFS9S-2015PL PFL-2018S DCL-2037 - RC5078 PBR-2022 - NEM020Z EMFS2016CZ -
Single-
phase
200V
class
2.2 VFS9S-2022PL PFL-2018S DCL-2037 - RC5078 PBR-2022 - NEM030Z EMFS2025DZ -
0.2 VFS9-2002PM PFL-2001S DCL-2002 NF3005A-MJ RC5078 PBR-2007 NEM011Z EMF2011BZ DIN001Z
0.4 VFS9-2004PM PFL-2005S DCL-2007 NF3005A-MJ RC5078 PBR-2007 - NEM011Z EMF2011BZ DIN001Z
0.75 VFS9-2007PM PFL-2005S DCL-2007 NF3005A-MJ RC5078 PBR-2007 - NEM011Z EMF2011BZ DIN001Z
1.5 VFS9-2015PM PFL-2011S DCL-2022 NF3015A-MJ RC5078 PBR-2022 - NEM011Z EMF2011BZ -
2.2 VFS9-2022PM PFL-2011S DCL-2022 NF3015A-MJ RC5078 PBR-2022 - NEM031Z EMF4022DZ -
3.7 VFS9-2037PM PFL-2018S DCL-2037 NF3020A-MJ RC5078 PBR-2037 - NEM031Z EMF4022DZ -
5.5 VFS9-2055PL PFL-2025S DCL-2055 - RC9129 PB3-2055 - NEM040Z EMF4045EZ -
7.5 VFS9-2075PL PFL-2050S DCL-2110 - RC9129 PBR-2075 - NEM040Z EMF4045EZ -
11 VFS9-2110PM PFL-2050S DCL-2110 NF3050A-MJ RC9129 PBR-2110 - NEM050Z EMF2080GZ
Three-
phase
200V
class
15 VFS9-2150PM PFL-2100S DCL-2220 NF3080A-MJ RC9129 PBR-2150 - NEM050Z EMF2080GZ -
0.75 VFS9-4007PL PFL-4012S DCL-2007 - RC5078 PBR-2007 MSF-4015Z NEM020Z EMF4006CZ -
1.5 VFS9-4015PL PFL-4012S DCL-2007 - RC5078 PBR-2007 MSF-4015Z NEM020Z EMF4006CZ -
2.2 VFS9-4022PL PFL-4012S DCL-2022 - RC5078 PBR-2007 MSF-4037Z NEM030Z EMF4022DZ -
3.7 VFS9-4037PL PFL-4012S DCL-2022 - RC5078 PBR-2007 MSF-4037Z NEM030Z EMF4022DZ -
5.5 VFS9-4055PL PFL-4025S DCL-4110 - RC9129 PBR3-4055 MSF-4075Z NEM040Z EMF4045EZ -
7.5 VFS9-4075PL PFL-4025S DCL-4110 - RC9129 PBR3-4075 MSF-4075Z NEM040Z EMF4045EZ -
Three-
phase
400V
class
11 VFS9-4110PL PFL-4025S DCL-4110 - RC9129 PBR3-4110 MSF-4150Z NEM050Z EMF4045FZ -
15 VFS9-4150PL PFL-4050S DCL-4220 - RC9129 PBR3-4150 MSF-4150Z NEM050Z EMF4045FZ -
Note 1: This filter is used wound around the input-side power line. (Number of turns: 4 or more) This filter can
be installed on the output side, as well.
Note 2: Connecting this reactor to the inverter makes it compliant with the standard "General Inverter (input
current of 20A or less) Harmonic Suppression Measures Execution Guidelines" set by the Japan Elec-
tric Industry Association.