E6580757
M-4
13
(Continued overleaf)
Error code Problem Possible causes Remedies
DC braking
• DC braking in process • Normal if the message disappears after
several tens of seconds. (See Note 2.)
Parameters in the
process of initializa-
tion
• Parameters are being initialized to default
values.
• Normal if the message disappears after a
while (several seconds to several tens of
seconds).
Setup parameters in
the process of being
set
• Setup parameters are in the process of
being set.
• Normal if the message disappears after a
while (several seconds to several tens of
seconds).
Auto-tuning in proc-
ess
• Auto-tuning is in process. • Normal if the message disappears after
several seconds.
(Note 1) ST : Terminal of stand by function.
(Note 2) When the ON/OFF function is selected for DC braking (DB), using the input terminal selection pa-
rameter, you can judge the inverter to be normal if "
" disappears when opening the circuit between
the terminal and CC.
[Alarms displayed during operation]
Overcurrent alarm Same as (overcurrent)
Overvoltage alarm Same as (overvoltage)
Overload alarm Same as / (overload)
Overheat Same as (overheat)
If two or more problems arise simultaneously, one of the following alarms appears and blinks.
, ,
The blinking alarms , , , are displayed in this order from left to right.