Toshiba VF-S9 Power Supply User Manual


 
E6580757
K-6
11
Torque boost parameters
Title Communication
No.
Function Unit Minimum
setting unit
Adjustment range Default
setting
User
setting
Reference
0400 Auto-tuning - - 0: Auto-tuning disabled (use of inter-
nal parameters)
1: Application of individual settings of
to
2: Auto-tuning enabled (returns to 1
after auto-tuning)
06.13
0401 Slip frequency Hz - 0.0-10.0 *2 6.13
0402 Motor primary
constant
- - 0-255 *2 6.13
0403 Motor secondary
constant
- - 0-255 *2 6.13
0404 Motor excitation
constant
- - 0-255 *2 6.13
0405 Magnification of
load inertial mo-
ment
Times - 0-200 0 6.13
0408 Rated capacity
ratio of motor to
inverter
- - 0: Same capacity as inverter
1: One-size smaller than inverter
06.13
Acceleration/deceleration time parameters
Title Communication
No.
Function Unit Minimum
setting unit
Adjustment range Default
setting
User
setting
Reference
0500 Acceleration
time 2
s 0.1 0.1-3600 10.0 6.14
0501 Deceleration
time 2
s 0.1 0.1-3600 10.0 6.14
0502 Acceleration/
deceleration 1
pattern
-- 0 6.14
0503 Acceleration
deceleration 2
pattern
--
0: Linear
1: S-pattern 1
2: S-pattern 2
06.14
0504 Acceleration/
deceleration pat-
tern selection
(1 or 2)
- - 0: Acceleration/deceleration 1
1: Acceleration/deceleration 2
06.14
0505 Acceleration/
deceleration 1 and
2 switching
frequency
Hz 0.1 0- 0.0 6.14
Protection parameters
Title Communication
No.
Function Unit Minimum
setting unit
Adjustment range Default
setting
User
setting
Reference
0600 Motor electronic-
thermal protection
level 1
%/(A) 1 10-100 100 6.15.1
0601 Stall prevention
level
%/(A) 1 10-199
200 (disabled)
150 6.15.2
0602 Inverter trip reten-
tion selection
- - 0: Not retained
1: Retained
0 6.15.3
0603 External input trip
stop mode selec-
tion
- - 0: Coast stop
1: Slowdown stop
2: Emergency DC braking
0 6.15.4
0604 Emergency DC
braking time
s 0.1 0.0-20.0 1.0 6.15.4
0605 Output phase
failure detection
mode selection
- - 0: Disabled
1: Enabled (during operation)
2: Enabled (disabled during auto-restart)
0 6.15.5