6.3.3 Modifying output terminal functions
: Output terminal selection 1 (RY-RC)
: Output terminal selection 2 (OUT)
: Output terminal selection 3 (FLA/B/C)
Use the above parameters to send various signals from the inverter to external equipment.
Up to 30 functions can be used by setting special parameters for the RY-RC, OUT, and FL (FLA, FLB, FLC)
terminals on the control terminal board.
Examples of application
Function of RY-RC:
Can be set using parameter .
Function of OUT:
Can be set using parameter .
Function of FLA/B/C:
Can be set using parameter .
FLA
FLC
RY
RC
P24
OUT
FL
RY
RY
FLB
Setting of output terminal function
Terminal
symbol
Title Function Adjustment range Default setting
RY-RC Output terminal selection 1
4 (Low-speed
detection signal)
OUT Output terminal selection 2
6 (Designated
frequency reach)
FL Output terminal selection 3
029
(see Section 11)
10
(Failure FL)
Sink logic/source logic output (OUT)
Sink logic/source logic (output terminal logic) switching is possible.
See Section 2.3 for further details.