Toshiba VF-S9 Power Supply User Manual


 
E6580757
B-9
2
Terminal
symbol
Input/output Function
Electrical
specifications
Inverter internal circuits
OUT Output
Multifunction programmable open collector
output. Standard default settings detect
and output speed reach signal output fre-
quencies.
Open collector out-
put : 24Vdc-50mA
*Sink-source
switchable
(JP301A)
RC
RY
Output
Multifunction programmable relay contact
output. Contact ratings: 250Vac -2A (cosφ
= 1), 30Vdc-1A, 250Vac-1A (cosφ = 0.4).
Standard default settings detect and out-
put low-speed signal output frequencies.
250Vac-2A (cosφ =
1)
: at resistance load
30Vdc-1A
: 250Vac-1A (cosφ
= 0.4)
RC
+24V
RY
RY
FLA
FLB
FLC
Output
Multifunction programmable relay contact
output. Contact ratings: 250Vac -2A (cosφ
= 1), 30Vdc-1A, 250Vac-1A (cosφ = 0.4).
Detects the operation of the inverter's
protection function. Contact across FLA-
FLC is closed and FLB-FLC is opened
during protection function operation.
250Vac-2A (cosφ =
1)
: at resistance load
30Vdc-1A
: 250Vac-1A (cosφ
= 0.4)
FLB
FLC
FLA
+24V
RY
150
5V
24V
OUT
JP301
SOURCE
10
10
150
FUSE