Toshiba VF-S9 Power Supply User Manual


 
E6580757
A-16
1
1.4.4 Installation
Installation environment
The VF-S9 Inverter is an electronic control instrument. Take full consideration to installing it in the proper
operating environment.
Danger
Prohibited
Do not place any inflammable substances near the VF-S9 Inverter. If an accident occurs in which flame
is emitted, this could lead to fire.
Mandatory
Operate under the environmental conditions prescribed in the instruction manual.
Operations under any other conditions may result in malfunction.
Warning
Prohibited
Do not install the VF-S9 Inverter in any location subject to large amounts of vibration.
This could cause the unit to fall, resulting in bodily injury.
Mandatory
Check to make sure that the input power voltage is +10%, -15% of the rated power voltage written on
the rating label (±10% when the load is 100% in continuous operation)
If the input power voltage is not +10%, -15% of the rated power voltage (±10% when the load is 100%
in continuous operation) this may result in fire.
Warning
Prohibited
Avoid operation in any location where there is direct spraying of the following solvents or other chemi-
cals. The plastic parts may be damaged to a certain degree depending on their shape, and there is a
possibility of the plastic covers coming off and the plastic units being dropped.
If the chemical or solvent is anything other than those shown below, please contact us in advance.
Note: The plastic cover has resistance to deformation by the above applicable solvents. They are
not examples for resistance to fire or explosion.
(Table 1) Examples of applicable chemicals
and solvents
Chemical Solvent
Hydrochloric acid
(density of 10% or less)
Methanol
Sulfuric acid (density of
10% or less)
Ethanol
Nitric acid (density of
10% or less)
Triol
Caustic soda Mesopropanol
Ammonia Glycerin
Sodium chloride (salt)
(Table 2) Examples of inapplicable
chemicals and solvents
Chemical Solvent
Phenol Gasoline,
kerosene, light oil
Benzenesulfonic
acid
Turpentine oil
Benzol
Thinner