12. Specifications
12.1 Models and their standard specifications
Standard specifications
Item Specification
Input voltage 3-phase 200V
Applicable motor (kW) 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Type VFS9-
Form 2002PM 2004PM 2007PM 2015PM 2022PM 2037PM 2055PL 2075PL 2110PM 2150PM
Capacity (kVA)
Note 1)
0.6 1.3 1.8 3.0 4.2 6.7 10 13 21 25
Rated output current
(A)
Note 2)
1.5
(1.5)
3.3
(3.3)
4.8
(4.4)
7.8
(7.5)
11.0
(10.0)
17.5
(16.5)
27.5
25.0
33
(33)
54
(49)
66
(60)
Rated output voltage
Note 3)
3-phase 200V to 230V
Rating
Overload current rating 60 seconds at 150%, 0.5 seconds at 200%
Voltage-frequency 3-phase 200V to 230V – 50/60Hz
Power
supply
Allowable fluctuation
Voltage + 10%, -15%
Note 4)
, frequency ±5%
Protective method IP20 Enclosed type (JEM1030)
Cooling method
Self
cooling
Forced air-cooled
Color Munsel 5Y+8/0.5
Built-in filter Standard EMI filter
High-attenuation EMI filter
Standard EMI filter
Item Specification
Input voltage 1-phase 200V 3-phase 400V
Applicable motor (kW) 0.2 0.4 0.75 1.5 2.2 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Type VFS9S- VFS9-
Form 2002PL 2004PL 2007PL 2015PL 2022PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL
Capacity (kVA)
Note 1)
0.6 1.3 1.8 3.0 4.2 1.8 3.1 4.2 7.2 11 13 21 25
Rated output current
(A)
Note 2)
1.5
(1.5)
3.3
(3.3)
4.8
(4.4)
7.8
(7.5)
11.0
(10.0)
2.3
(2.1)
4.1
(3.7)
5.5
(5.0)
9.5
(8.6)
14.3
(13.0)
17.0
(17.0)
27.7
(25.0)
33
(30)
Rated output voltage
Note 3)
3-phase 200V to 240V 3-phase 380V to 500V
Rating
Overload current rating 60 seconds at 150%, 0.5 seconds at 200% 60 seconds at 150%, 0.5 seconds at 200%
Voltage-frequency 3-phase 200V to 240V – 50/60Hz 3-phase 380V to 500V – 50/60Hz
Power
supply
Allowable fluctuation
Voltage +10%, -15%
Note 4)
, frequency ±5% Voltage +10%, -15%
Note 4)
, frequency ±5%
Protective method IP20 Enclosed type (JEM1030) IP20 Enclosed type (JEM1030)
Cooling method
Self
cooling
Forced air-cooled Forced air-cooled
Color Munsel 5Y+8/0.5 Munsel 5Y+8/0.5
Built-in filter High-attenuation EMI filter High-attenuation EMI filter
Note) 1. Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note) 2. Indicates rated output current setting when the PWM carrier frequency (parameter F300) is 4kHz or less.
When exceeding 4kHz, the rated output current setting is indicated in the parenthesis. When the input power voltage of
the 400V class model exceeds 480V, it is necessary to further reduce the setting. The default setting of the PWM car-
rier frequency is 12kHz.
Note) 3. Maximum output voltage is the same as the input voltage.
Note) 4.
±10% when the inverter is used continuously (load of 100%).