3Com 5500-SI Switch User Manual


 
Logging Function 471
Table 521 Info-Center-Defined Severity
Note that there is a slash between severity and digest.
6 Digest
The digest is abbreviation, it represent the abstract of contents.
Note that there is a colon between digest and content.
7 Content
It is the contents of logging information.
Info-Center
Configuration
The Switch supports six output directions of information.
The system assigns a channel in each output direction by default. See Table 522.
Table 522 Numbers and Names of the Channels for Log Output
The settings in the six directions are independent from each other. The settings will
take effect only after enabling the information center.
The Switch info-center has the following features:
Support to output log in six directions, that is, Console, monitor to Telnet terminal,
logbuffer, loghost, trapbuffer, and SNMP.
The log is divided into 8 levels according to the significance and it can be filtered
based on the levels.
The information can be classified in terms of the source modules and the
information can be filtered in accordance with the modules.
The output language can be selected between Chinese and English.
Severity Description
emergencies Extremely emergent errors
alerts Errors that need to be corrected immediately
critical Critical errors
errors Errors that need to be addressed but are not critical
warnings Warning, there may be some types of errors
notifications Information that should be noted
informational Common prompting information
debugging Debugging information
Output direction Channel number Default channel name
Console 0 console
Monitor 1 monitor
Info-center loghost 2 loghost
Trap buffer 3 trapbuf
Logging buffer 4 logbuf
snmp 5 snmpagent