AMD LX 700@0.8W Computer Hardware User Manual


 
AMD Geode™ LX Processors Data Book 331
Display Controller Register Descriptions
33234H
6.6.5.5 DC CRT Vertical Blank Timing (DC_V_BLANK_TIMING)
This register contains vertical blank timing information. All values are specified in lines. For interlaced display, no border is
supported, so blank timing is implied by the total/active timing.
6.6.5.6 DC CRT Vertical Sync Timing (DC_V_SYNC_TIMING)
This register contains CRT vertical sync timing information. All values are specified in lines.
DC Memory Offset 054h
Typ e R /W
Reset Value xxxxxxxxh
DC_V_BLANK_TIMING Register Map
313029282726252423222120191817161514131211109876543210
RSVD V_BLANK_END RSVD V_BLANK_START
DC_V_BLANK_TIMING Bit Descriptions
Bit Name Description
31:27 RSVD Reserved. These bits should be programmed to zero.
26:16 V_BLANK_END Vertical Blank End. This field represents the line at which the vertical blanking signal
becomes inactive minus 1. If the display is interlaced, no border is supported, so this
value should be identical to V_TOTAL.
15:11 RSVD Reserved. These bits should be programmed to zero.
10:0 V_BLANK_
START
Vertical Blank Start. This field represents the line at which the vertical blanking signal
becomes active minus 1. If the display is interlaced, this value should be programmed to
V_ACTIVE plus 1.
DC Memory Offset 058h
Typ e R /W
Reset Value xxxxxxxxh
DC_V_SYNC_TIMING Register Map
313029282726252423222120191817161514131211109876543210
RSVD V_SYNC_END RSVD V_SYNC_START
DC_V_SYNC_TIMING Bit Descriptions
Bit Name Description
31:27 RSVD Reserved. These bits should be programmed to zero.
26:16 V_SYNC_END Vertical Sync End. This field represents the line at which the CRT vertical sync signal
becomes inactive minus 1.
15:11 RSVD Reserved. These bits should be programmed to zero.
10:0 V_SYNC_
START
Vertical Sync Start. This field represents the line at which the CRT vertical sync signal
becomes active minus 1. For interlaced display, note that the vertical counter is incre-
mented twice during each line and since there are an odd number of lines, the vertical
sync pulse will trigger in the middle of a line for one field and at the end of a line for the
subsequent field.