Epson 7600 Printer User Manual


 
EPSON Stylus Pro 7600/9600 Revision A
Disassembly & Assembly Disassembly and Assembly of Cleaning Mechanism 198
4.6 Disassembly and Assembly of Cleaning
Mechanism
The Maintenance ASSY consists of the major assemblies listed below four of which
constitute the Cleaning Unit.
The life of the Cleaning Unit is judged by the life of the Pump Motor. Replace the Cap
ASSY, Pump ASSY, Flushing Box and Wiper at the same time.
Parts of the Cleaning Unit are available as individual parts so that each of those parts
can be replaced singly.
NOTE: For details, refer to Table 6-1 Stylus Pro 7600/9600 - Lives of
Periodically Replaced Components and Maintenance (p.277)”.
Table 4-4. Major Parts of Cleaning Mechanism
Names of Parts See
Pump Motor ASSY p.200
Cleaning Unit
* Replace at expiration of Pump Motor
ASSY life
Pump/Cap ASSY Cap ASSY p.200
Pump ASSY p.201
Cleaner Head p.203
Flushing Box ASSY p.204
A D J U S T M E N T
R E Q U I R E D
Once you have replaced the Cleaning Unit, be sure to execute
CLEAR COUNTERS “Initialize cleaning unit (CLEANER) (p.71)”
and CLEAR COUNTERS “Initialize flashing box (FL BOX) (p.71)”
in Maintenance mode 2.