Epson 7600 Printer User Manual


 
EPSON Stylus Pro 7600/9600 Revision A
Adjustment Self-diagnostic Function 244
5.2.3.10 Platen Position (Sponge Position) Adjustment
Detect the position of each sponge on the platen. (See Figure 5-38)
For Platen R, input the deviation of the printed pattern from the left end of the
frame in which the sponge nearest to the 1st home is embedded.
For Platen L, input the deviation of the printed pattern from the left end of the
frame in which the 7th sponge counted from the home for Stylus Pro 7600 or
the 9th sponge for Stylus Pro 9600 is embedded.
Input a negative value for a deviation toward the home or a positive value for
a deviation toward the side opposite to the home.
Pattern drawing method: 360dpi, Uni-D, 240CPS, VSD2, Large
PLATEN POSITION (SPONGE POSITION) ADJUSTMENT PROCEDURE
1. Start the Self-diagnostic Function:
Power OFF
[Paper Feed
]
+
[Paper Feed
]+[Cut/Eject] Power ON
2. Display “Adj: Sponge Pos.”:
[Paper Feed
]
[SelecType >]
[Paper Feed
] x4
3. Print the pattern:
[Enter
]
x2
4. Measure the platen position R:
Using a measuring rule, measure the distance from the left end
of the frame in which
the sponge nearest to the 1st home is embedded
to the longitudinal line of the printed
pattern.
Input the measured value on the panel.
(See Figure 5-39)
5. Measure the platen position L:
Using a measuring rule, measure the distance from the left end
of the frame in which
the 7th sponge counted from the home for Stylus Pro 7600 or the 9th sponge for
Stylus Pro 9600 is embedded
to the longitudinal line of the printed pattern.
Input the measured value on the panel.
(See Figure 5-39)
Figure 5-38. Menu Transition for Platen Position Adjustment
Figure 5-39. Print Pattern for Platen Position Adjustment
[Enter] Adjust Print
Printing Pattern
Platen R:
?0.0mm
Platen L:
?0.0mm
Adj :
? Platen Pos. Chk.
[Enter]
[Paper Feed
]Key: +
[Paper Feed
]Key : –
*Setting is possible in increments of 0.1 mm.
Printing end
[Enter]
[Enter]
[Paper Feed
]Key: +
[Paper Feed
]Key : –
*Setting is possible in increments of 0.1 mm.
– side+ side– side
+
side
Measure this deviation Measure this deviation
Platen position (counted from home side)
Stylus Pro 7600: 7th
Stylus Pro 9600: 9th
Platen Position L Platen Position R