Epson 7600 Printer User Manual


 
EPSON Stylus Pro 7600/9600 Revision A
Adjustment Self-diagnostic Function 257
5.2.3.21 Counter Clear
[Description below is given only for information]
Table 5-24 indicates the counters to be cleared and their initial values and Figure 5-58
shows menu transition for counter clearing.
Note : The numeric value in ( ) represents the initial value in the area which firmware does not
use.
C A U T I O N
This function is to be used to initialize each counter value at the
factory before shipment. Never use this function on the service site.
(If you operate, all the counter values concerning ink system control
will be lost and no operation or control after that will be carried out
correctly.)
Table 5-24. Counters to be Cleared and Their Initial Values
Counters to be Cleared Initial Value
Protection Counter A 0
Protection Counter A Work 0
Protection Counter D 0
Protection Counter D Work 0
Protection Counter B 0
Protection Counter B Work 0
Ink Volume Counter Rb 0
Ink Volume Counter Rx 0
Ink Volume Counter Rz 0
Consumed Ink Counter K 0
Consumed Ink Counter LK 0
Consumed Ink Counter C 0
Consumed Ink Counter M 0
Consumed Ink Counter LC 0
Consumed Ink Counter LM 0
Consumed Ink Counter Y 0
CL1 Cumulative Counter 0
CL2 Cumulative Counter 0
CL3 Cumulative Counter 0
HP and Other Cumulative Counters 0
Timer CL Cumulative Counter 0
Yellow Shot Counter 1 0
Yellow Shot Counter 2 0
Accumulated Prints Timer 0
Timer for Timer CL Execution 1 0
Timer for Timer CL Execution 2 0
CL Flag 0 (Not during CL)
Initial Charge Counter 1 (Not completed)
Periodic Pseudo-Vacuum Flag (0)
Ink Type 0 (Neutral)
Ink OUT Judge Counter (0)
Vacuum Compensation Coefficient (90)
Discharge Compensation Coefficient (90)
Compensation Permission Flag H (0)
Cartridge Midway Replacement Flag 1 (Replaced)
CSIC Storage Area for Printer Body FFh
Cumulative Ink Consumption 0
Cumulative Paper Consumption 0
Ink Consumption during Nozzle Check 0
Paper Consumption during Nozzle Check 0
Counters to be Cleared 0
Y Ink Cumulative Discharge Counter 0
Previous Y Ink Cumulative Discharge Counter 0
Y Ink Cumulative Discharge at Previous Ultrasonic Cleaning (0)
Y Ink Cumulative Discharge at Previous Periodic CL2 Execution (0)
CSIC Control Flag 1 (All valid)
Maintenance Menu Ink Related Count 1 1 for date 0 for others
Timer Initial Charge Execution Count (0)
Initial Charge Previous Execution time (0)
Timer Initial Charge Flag (0)
Maintenance tank ink consumption (CSIC) 0
Head hot error flag 0 (Not error)
Borderless ink counter 0
Timer CL4 cumulative counter 0
Pump counter P 0
Maintenance tank detection 1 (ON)
CL5 cumulative counter 0
CL1 count with cleaning prohibited (7 colors) 0
Timer CL4 flag 0 (Not being executed)
Time having elapsed since previous K ink replacement sequence 0xffffffff
CL4 cumulative counter 0
K ink counter for ink system processing 0
Ink replacement sequence counter 0
Ink type changed MB flag 0 (Not changed)
Previous count-down ratio 0 (%)
Initial charge executed MB flag 0 (Not executed)
Initial charge executed MB flag 0
Table 5-24. Counters to be Cleared and Their Initial Values (continued)
Counters to be Cleared Initial Value