IBM Version 8.30 Computer Hardware User Manual


 
3. Click Next. The wizard turns off the PCI slot.
4. Click Next. The Replace the Controller window opens. This window lists the
steps that you must follow to replace the controller hardware in the server.
5. When complete, click OK. The wizard does the following:
a. Turns on the PCI slot.
b. Verifies that the controller is working properly.
c. Configures the controller by importing the configuration from the physical
drives.
Note: Configuration can take several minutes.
.
6.
Click Next.
7. Click Finish.
More information
v Steps for hot-replacing a ServeRAID controller
v Using Active PCI features
Configuring
a ServeRAID controller: the basic steps: The following steps are an
overview of the ServeRAID configuration process:
1. In the Enterprise view, click
(controller) that you want to configure.
2. Right-click Create logical drive, or click
in the Logical devices view. The
Configuration wizard opens.
3. Click either Express configuration or Custom configuration: If you select
Express configuration, the ServeRAID Manager automatically:
a. Creates one or more arrays, based on the number and size of ready physical
drives in your system.
b. Defines a hot-spare drive, if four or more ready physical drives of the same
size are available.
c. Defines a logical drive for each array.
If
you select Custom configuration, the ServeRAID Manager walks you
through:
a. Selecting the physical drives that you want to include in your arrays or
create as hot-spare drives.
b. Defining the logical drives for your arrays.
4.
Click Automatically initialize new logical drives. Initializing a logical drive
erases the first 1024 sectors on the drive and prevents access to any data
previously stored on the drive.
5. Click Next; then, review the configuration summary.
6. Click Apply. The ServeRAID Manager will configure the controller and
initialize and synchronize the logical drives.
For HostRAID controllers, Express configuration creates a
single logical drive. Custom configuration allows you to select the physical drives
and segments used to define your logical drives.
More information
v Example: Express configuration
v Choosing between Express and Custom configuration (SAS, SATA, HostRAID)
112 ServeRAID Manager Installation and User's Guide