v SCSI-2
v SCSI-1
This value is available if your controller is set to SCSI-1; otherwise, SCSI-1 does
not appear in the menu.
Ports
[numbers] object: Use this object, in the Physical devices view, to work
with selected ports or to display their properties:
Possible subobject
v
(Physical drive)
v
(Hot-spare drive)
Warning
and error conditions
v None.
Actions
v Scan for new or removed ready drives
Physical
drive [number] object: Use this object, in the Physical devices view, to
work with a physical drive or to display its properties.
Note: A SCSI channel supports a maximum 15 physical drives.
Possible subobject
None.
Warning and error conditions
v
(warning) is displayed if the selected physical drive is undergoing a rebuild
operation, reports a PFA, or is a non-warranted physical drive.
v
(error) is displayed if the selected physical drive is a defunct drive.
Actions
v Identify physical drive
v If the drive is ready:
– Create hot-spare drive
– Create standby hot-spare drive
– Create assigned hot-spare drive
– Clear
– Verify
– Initialize
v Rebuild drive
v If the drive is defunct, Remove the defunct drive
v Set drive state to online
v Change write-cache mode to write back or write through
Chapter 4. Managing ServeRAID devices 137