Enclosure management device object: Use this object, in the Physical devices
view, to work with a storage enclosure attached to controller with a SAF-TE
processor.
Note: The integrated RAID controller does not support enclosure monitoring. Any
enclosure in an integrated RAID controller RAID subsystem is displayed in
the ServeRAID Manager Enterprise view; however, the ServeRAID Manager
and the ServeRAID Manager agent will not generate any events or enclosure
status information.
Possible subobject
None.
Warning and error conditions
v
(warning) is displayed if the enclosure has the following conditions:
– A fan has failed.
– A power supply has failed.
v
(error) is displayed if the enclosure has the following conditions:
– It is not responding.
– It is overheating.
– Multiple fans have failed.
– Multiple power supplies have failed.
v
(enclosure) is displayed if the enclosure is one of the following:
– Working properly.
– Not supported.
– Supported, but not monitored for problems. For example, enclosures that are
internal to a server do not have separate fans or power supplies.
Actions
Identify enclosure
CD-ROM drive object: Use this object to display CD-ROM drive properties.
Note: The ServeRAID-5i, 6i/6i+, 6M, and 7t controllers do not support CD-ROM
drives.
Possible subobject
None.
Warning and error conditions
CD-ROM drive objects cannot have warning or error conditions.
Actions
None.
Removable-media drive object: Use this object to display removable-media drive
properties.
Chapter 4. Managing ServeRAID devices 147