IBM Version 8.30 Computer Hardware User Manual


 
Set drive to defunct: controller [number], < device location>
Explanation:
A user used the operating-system utilities to mark the specified physical drive
defunct.
Action:
Rebuild the critical array.
Set drive to defunct: controller [number], < device location>
Explanation:
The specified physical drive is not part of a valid configuration but was found in a
cluster setup.
Action:
Rebuild the specified physical drive into an array. If you cannot rebuild the
physical drive, replace or remove the physical drive.
Set drive to defunct: controller [number], < device location>
Explanation:
The specified physical drive is not part of a valid configuration but was found in a
cluster setup.
Action:
Rebuild the specified physical drive into an array. If you cannot rebuild the
physical drive, replace or remove the physical drive.
Set drive to defunct: controller [number], < device location>
Explanation:
The specified physical drive is configured as part of another system.
Action:
Rebuild the specified physical drive into an array on this system. If you cannot
rebuild the physical drive, replace the physical drive.
Set drive to defunct: controller [number], < device location>
Explanation:
The specified channel or port is not working.
Action:
1. Verify that there is power to external enclosures and connections.
2. Verify that cables are properly seated.
250 ServeRAID Manager Installation and User's Guide