IBM Version 8.30 Computer Hardware User Manual


 
Note: This action is not supported when using the following:
1. Integrated RAID controller
2. ServeRAID-5i controller
3. ServeRAID-6i/6i+ controller
4. ServeRAID-7t controller
5. ServeRAID-8i controller
6. ServeRAID-8k/8k-l controller
7. HostRAID controller
Use
this action to force a failover from the active to the passive controller for the
following reasons:
v To test your failover configuration.
v If you are having problems accessing data through ServeRAID, attempt to
failover to see if that fixes the problem.
Note:
1. This action is available only if clustering is enabled.
2. Failover detects only failed controllers.
1.
In the Enterprise view, click
(controller).
2. Right-click Clustering actions Fail from active to passive.
3. Click Yes to confirm the failover.
Networked storage object: Use this object, in the Enterprise view, to work with
the management stations and network-attached enclosures in your configuration or
to display their properties. When you click this object, the ServeRAID Manager
displays a summary of management stations in the Networked storage view.
Possible subobject
v
(Management station)
v
(Display group)
Warning
and error conditions
v
(warning) is displayed if any management station has a warning or error
condition.
Actions
v Add management station
v Remove management station
v Update controller images
Management
station object: Use this object, in the Enterprise view, to work with
a managment station or to display its properties.
Possible subobject
v
(Enclosure)
Warning
and error conditions
v
(warning) is displayed if any enclosure has a warning or error condition.
114 ServeRAID Manager Installation and User's Guide