3. Retry the command.
4. If the command still fails, restart the server and retry the command.
Could not delete the hot-spare drive: controller [number], < drive
location> Could not delete the standby hot-spare drive: controller
[number], < drive location>
Explanation:
The hot-spare drive or standby hot-spare drive could not be deleted because a
hardware error occurred.
Action:
1. Verify that the controller, cables, and physical drives are installed properly.
2. Verify that there is power to the physical drives.
3. Retry the command.
4. If the command still fails, restart the server and retry the command.
If
the problem persists, replace the specified drive.
Could not set the merge-group number: controller [number], logical
drive [number]
Explanation:
The specified merge-group number could not be set because a hardware error
occurred.
Action:
1. Verify that the controller, cables, and physical drives are installed properly.
2. Verify that there is power to the physical drives.
3. Retry the command.
4. If the command still fails, restart the server and retry the command.
5.
If the problem persists, contact your service representative.
Could not blink the device lights
Explanation:
The device lights could not flash because of one of the following:
v The physical drives are not managed by an enclosure.
v A hardware error occurred.
Action:
Verify that the device is managed by an enclosure (SAF-TE) device on the SCSI
drive channel. If it is, complete the following steps:
1. Verify that the controller, cables, and physical drives are installed properly.
2. Verify that there is power to the physical drives.
Chapter 5. Troubleshooting ServeRAID Manager 221