IBM Version 8.30 Computer Hardware User Manual


 
Action:
1. Verify that the controller, cables, and physical drives are installed properly.
2. Verify that there is power to the physical drives.
3. Retry the command.
4. If the command still fails, restart the server and retry the command.
5. If the problem persists, contact your service representative.
Enclosure fan [number] is malfunctioning: controller [number],
channel [number]
Explanation:
A hardware error occurred.
Action:
Verify that the fan in the enclosure device is installed properly. If it is, complete the
following steps:
1. Verify that the controller, cables, and physical drives are installed properly.
2. Verify that there is power to the physical drives.
3. Retry the command.
4. If the command still fails, restart the server and retry the command.
If
the problem persists, replace the specified fan.
Enclosure power supply [number] is malfunctioning: controller
[number], channel [number]
Explanation:
A hardware error occurred.
Action:
Verify that the power supply in the enclosure device is installed properly. If it is,
complete the following steps:
1. Verify that the controller, cables, and physical drives are installed properly.
2. Verify that there is power to the physical drives.
3. Retry the command.
4. If the command still fails, restart the server and retry the command.
If
the problem persists, replace the specified power supply.
Enclosure temperature is out of normal range: controller [number],
channel [number]
Explanation:
A hardware error occurred.
242 ServeRAID Manager Installation and User's Guide