Sun Microsystems 5310 NAS Server User Manual


 
Chapter 2 NAS Head 2-81
PROMPT> rpcinfo -p <StorEdge-hostname>
programversprotoport
1000002tcp111portmapper
1000002udp111portmapper
...
8058985771udp693webadmin
In the above example, UDP port 693 would have to be opened. The port is always in
the range 600 to 1023 but may vary based on system parameters.
The keyboard arrows keys do not respond properly when using
telnet to the StorEdge
The arrow keys generally do not work within StorEdge Telnet menus, and often
cause an immediate exit from the current screen.
Use only the following keys within the Telnet menus:
[Backspace] or [Del]Deletes the previous character.
[Ctrl]+UDeletes the entire current field.
[Esc]Exits the menu with no change.
[Enter] or [Tab]Enters data and proceeds to the next field.
If no data entered, proceeds to the next field with no change.
Having problems after software upgrade, how do I return to the
previous version?
1. Access the StorEdge via Telnet.
2. Press [Enter] at the [menu] prompt and enter the administrator password.
3. Enter “0”, “Shutdown” in the operations Section.
4. Enter “P”, “Boot previous version”.
5. At the verification screen, enter “Y”, “Yes” to continue or [Esc] to cancel.
System reboots and loads previous version of software
This functionality is also available from the StorEdge Web Admin.