7-20 Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004
8. Replace the chassis cover if you have no additional work to do inside the chassis.
FIGURE 7-8 The Flash Disk
Note – After completing the flash disk replacement, you must recover the
configuration information to bring the system back online.
7.6.10.3 Upgrade and Configuration Recovery
In this step, you will restore the system configuration and upgrade from the base
operating system to a full version of the OS. The base OS contains only a limited
subset of the StorEdge functionality, and cannot access the RAID volumes. Please
note that this upgrade procedure is only valid when upgrading from the Base OS.
The standard OS upgrade procedure is described elsewhere.
1. Configure the server's IP address. This may be done automatically at startup via
DHCP or it can be configured manually via the LCD display or the console Host
Name & Network screen. Please see the software manual or the FAQ for IP setup
instructions.
2. Telnet to the StorEdge at the newly assigned IP address. Verify that the system is
running the Base OS by entering the version command on the CLI. Confirm that
the output is similar to the following:
StorEdge Model INSTALL S/N 0 Version 4.02 M38 (Build 154)
3. Connect to the upgrade page on the server. The upgrade page is used to send the
latest OS image to the server. The URL for the upgrade page is (please note the
dot before BUILT-IN):
Flash Disk