Chapter 1 Troubleshooting Overview 1-25
Fan Error Fan Failure:
Blower fan xx has failed. Fan speed = xx
RPM.
Action: The fan must be replaced as soon
as possible. If the temperature begins to
rise, the situation could become critical.
Severity = Error
envFanFail trap P11 Fan xx
failed
Blower fan
xx has failed!
Power
Supply
Module
Failure
Power supply failure:
The power supply unit xx has failed.
Action: The power supply unit must be
replaced as soon as possible. Severity =
Error
envPowerFail
trap
P12 Power
xx failed
Power
supply unit
xx has failed.
Power
Supply
Module
Temperature
Power supply temperature critical:
The power supply unit xx is overheating.
Action: Replace the power supply to
avoid any permanent damage. Severity =
Critical
envPowerTemp
Critical trap
P22 Power
xx
overheated
Power
supply unit
xx is
overheating.
Temperature
Error
Temperature critical:
Temperature in the system is critical. It is
xxx Degrees Celsius.
Action: 1. Check for any fan failures, OR
2. Check for blockage of the ventilation,
OR
3. Move the system to a cooler place.
Severity = Error
envTemperatue
Error trap
P51 Temp
error
The
temperature
is critical.
Primary
Power Cord
Failure
Power cord failure:
The primary power cord has failed or
been disconnected.
Action: 1. Check the power cord
connections at both ends, OR
2. Replace the power cord.
Severity = Error
envPrimary
PowerFail trap
P31 Fail
PWR cord 1
The primary
power cord
has failed.
Secondary
Power Cord
Failure
Power cord failure:
The secondary power cord has failed or
been disconnected.
Action: 1. Check the power cord
connections at both ends, OR
2. Replace the power cord.
Severity = Error
envSecondary
PowerFail trap
P32 Fail
PWR cord 2
The
secondary
power cord
has failed.