Sun Microsystems 5310 NAS Server User Manual


 
Chapter 7 FRU/CRU Replacement Procedures 7-39
10. Choose one of the following steps, based on the status of the Active and Fault
lights:
Active light is off - The drive may be installed incorrectly. Remove the drive, wait
30 seconds, and then reinstall it. When finished, go to step 12.
Fault light is illuminated - The new drive may be defective. Replace it with
another new drive, and then go to step 12.
Active lights are on and Fault lights are off - Go to step 13. 12 Is the problem
corrected?
Yes - Go to step 13.
No - Contact technical support.
11. Remove the antistatic protection.
12. Bring the new drive online using the storage management software.
13. Complete any remaining Recovery Guru procedures, if needed.
14. Check the status of all modules in the storage array.
15. Do any components have a Needs Attention status?
Yes - Select the Recovery Guru toolbar button in the Array Management Window
and complete the recovery procedure. If the problem persists, contact technical
support.
No - Go to step 18.
16. Create, save, and print a new storage array profile.
End Of Procedure
7.7.4 Replacing a Fan
Use the following procedure to replace a fan in a command module. Figure 7-22
illustrates inserting and removing a fan.
7.7.4.1 Tools and Equipment
Antistatic protection
Replacement fan
7.7.4.2 Procedure
1. If needed, use the storage management software to create, save, and print a new
storage array profile.
2. Did the Recovery Guru direct you to replace a failed fan?