Sun Microsystems 5310 NAS Server User Manual


 
7-40 Sun StorEdge 5310 NAS Troubleshooting Guide December 2004
Yes - Go to step 3.
No - Run the Recovery Guru to identify the failed component. Go to step 3.
3. Remove the back cover.
4. If needed, mute the alarm.
Caution – Electrostatic discharge damage to sensitive components. To prevent
electrostatic discharge damage to the module, use proper antistatic protection when
handling the module components.
5. Put on antistatic protection.
6. Unpack the new fan.
Set the new fan on a dry, level surface. Save all packing materials in case you need to
return the fan.
7. If the storage management software instructs you to do so, turn off both power
switches on the module. Otherwise, leave the power on.
8. Check the Fault lights to locate the failed fan. If a fan has a fault, its light will be
illuminated and amber.
9. Slide the latch left or right (up or down on a deskside model) on the failed fan to
unlock the component, and then pull on the knob to remove the failed fan.
FIGURE 7-22 Replacing a Fan
10. Slide the new fan all the way into the empty slot, until it snaps into place.
11. If you turned off the power in step 7, turn it on again.
12. Based on the status of the fan Fault light, choose one of the following steps: