Sun Microsystems 5310 NAS Server User Manual


 
1-28 Sun StorEdge 5310 NAS Troubleshooting Guide December 2004
2. Wear a wrist strap, and always be properly grounded when touching static-
sensitive equipment/parts.
If a wrist strap is not available, touch any unpainted metal surface on the Sun
StorEdge 5310 NAS (and optional Sun StorEdge 5310 NAS Expansion Unit) back
panel to dissipate static electricity. Repeat this procedure several times during
installation.
3. Avoid touching exposed circuitry, and handle components by their edges only.
Caution – Do not power on the Sun StorEdge 5310 NAS nor Sun StorEdge 5310
NAS Expansion Unit units until after you have connected to the Network.
The AC source must be electrically isolated by double or reinforced insulation from
any hazardous AC or DC source. The AC source must be capable of providing up to
500 W of continuous power per feed pair.
Mains AC Power Disconnect—You are responsible for installing an AC power
disconnect for the entire rack unit. This power source disconnect must be readily
accessible, and it must be labeled as controlling power to the entire unit, not just to
the server(s).