Sun Microsystems 5310 NAS Server User Manual


 
Chapter 7 FRU/CRU Replacement Procedures 7-13
7.6.6 Gigabit Ethernet Card
Note – Add-in cards must be replaced while the riser board is removed from the
chassis.
The server supports 3V only and Universal PCI cards. It does not support 5V only
cards. Alternately, a 10/100 Ethernetcard may be used for Cluster HeartBeat . The
procedure to replace the 10/100 Ethernet is the same as the fibre Ethernet card.
Caution – Before touching or replacing any component inside the Sun StorEdge
5310 NAS, disconnect all external cables and follow the instructions in “Safety:
Before You Remove the Cover” on page 7-2 and “Removing and Replacing the
Cover” on page 7-2. Always place the server on a grounded ESD pad and wear a
properly grounded antistatic wrist strap.
To replace a PCI card, follow these steps:
1. Before removing the cover to work inside the system, observe the previously
stated safety guidelines.
2. Remove the chassis cover.
3. Disconnect the network cable from the interface on the network card.
4. Insert your finger in the plastic loop on the PCI riser assembly.
5. Pull straight up and remove the riser assembly from the chassis.
6. Open the retainer clip on the riser card retention bracket.
7. Pull the PCI card out of the riser board slot.
8. Install the new PCI add-in card on the riser assembly.
9. Insert the riser assembly connector in the server board slot while aligning the tabs
on the rear retention bracket with the holes in the chassis.
10. Firmly press the riser assembly straight down until it is seated in the server board
slot.