7. Touch the Network Name (SSID) field and from the Service Set Identifier keyboard, enter the SSID
name you will be using on your target Wireless Access Point (case sensitive).
The card should be given the SSID used by the target WAP. If this field is left blank, the unit
will attempt to connect to the first available WAP. By default, all WAP200Gs use AMX as
their assigned SSID value.
One of the most common problems associated with connection to a WAP arise because the
SSID was not entered properly. You must maintain the same case when entering the SSID
information. ABC is not the same as Abc.
The alpha-numeric string is by default AMX but can later be changed to any 32-character
entry. This string must be duplicated within the Network Name (SSID) field on the WAP.
As an example, if you use TECHPUBS as your SSID, you must match this word and the
case within both the Network Name (SSID) field on the touch panel’s Network Name SSID
field and on the WAP’s Basic Wireless Configuration page.
8. Leave the Authentication field reading Open System (default).
Open System Authentication allows any device to join the network if the panel’s SSID
matches the WAP’s SSID. An Open System is recommended for communication between
Modero panels and an NXA-WAP200G.
Shared Key Authentication requires that the panel and the Wireless Access Point have the
same WEP Key to authenticate.
9. Toggle the Encryption field (FIG. 81) until it reads WEP64 or WEP128. The 64/128 selection
reflects the bit-level of encryption security. This WEP encryption level must match the encryption
level being used on the WAP.
FIG. 81 Wireless Settings page (Wireless Settings section)
Mini-PCI wireless card communication
settings (for use with a target WAP)
SSID field
Changes on this page take
effect after using the BACK
button to return to the
previous page
You must first take the SSID name, Current Key string value, and panel MAC
Address information and then later enter it into the appropriate WAP dialog fields in
order to "sync-up" the secure connection. These values must be identically
reproduced on the target WAP.
WEP will not work unless the same Default Key is set on both the panel and the
Wireless Access Point.
For example: if you have your Wireless Access Point set to default key 4 (which
was 01:02:03:04:05), you must set the panel’s key 4 to 01:02:03:04:05.