AMX NXD/NXT-1500VG Computer Monitor User Manual


 
Installation Procedures: 12" and 15" Panels
59
VG-Series Modero Touch Panels
Installation of the NXD Touch Panel
The NXD panel can be installed either directly into the (optional) CB-TP12/15 or other solid surface
environment using the two different mounting options: drywall clips or solid surface screws. The
following sections describe mounting the touch panel directly into a pre-wall installed conduit box, a
solid surface or drywall, and optional NXA-RK Rack Mount Kit.
Installing the NXD panel within a Conduit Box
The conduit box must be mounted prior to continuing this section. Refer to the procedures in the
Pre-wall Installation of the Conduit Boxes section on page 58 for detailed pre-wall installation
instructions. Verify that all necessary cables have been threaded through the knockouts on the conduit
box and the connections have been tested prior to installation of the NXD panel.
1. Remove the magnetic faceplate/bezel (A in FIG. 39) from the main NXD unit (B in FIG. 39) by
gripping the faceplate and pulling with gentle outward force.
2. Verify the incoming RJ-45, Ethernet, USB, and any other audio/video cables have been properly
threaded through the wiring knockouts (from their terminal locations) on the conduit box. Leave
enough slack in the wiring to accommodate any re-positioning of the panel.
3. Connect all data and power wiring connectors to their corresponding locations along the side of the
(un-powered) NXD touch panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging
in the 2-pin power connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF
transmitter.
FIG. 39 Wall Mount panel installation configuration for pre-existing conduit/wallbox in a pre-wall construction
B - Main NXD unit consists of
C - Optional CB-TP
Install the four #4-40
screws into the places
indicated
Stud
the touch panel and backbox housing
conduit/wallbox
Cable
knockouts
Installed flush
against the
finished wall
Do not use these
tabs to mount
the conduit /wallbox
These are ONLY used to
secure the main unit to the CB
SURFACE
surface
A - Faceplate
(bezel)
Mounting Tab