AMX NXD/NXT-1500VG Computer Monitor User Manual


 
Installation Procedures: 12" and 15" Panels
54
VG-Series Modero Touch Panels
Removing the Original Modero Back Box
1.
Detach all connectors from the side of the touch panel.
2. Remove the magnetic faceplate from the NXD unit by gripping the faceplate and pulling outwards
while applying a small amount of pressure to remove it from the main unit.
3. Place the LCD face-down on a soft cloth to expose the back of the panel and prevent scratching of
the LCD.
4. Unscrew the Stereo Output nut from the Stereo Output jack.
5. Remove the I/O connector plate by using a grounded Phillips-head screwdriver to remove the two
screws and slide the I/O connector plate away from the back box housing.
6. Remove the four pan-head Housing Screws from the rear of the NXD unit (FIG. 33). These screws
secure the back box to the internal panel casing.
7. Lift the back box housing to separate it from the internal panel casing.
Installing the MP-TP12/15 Back Box
1.
Unscrew the four pan-head Housing screws (#8-32) from the MP-TP12/15 rear plastic cover.
2. Gently place the MP-TP12/15 back box over the internal panel casing (with the cable routing hole
on the right-side of the panel).
3. Re-install and secure the four pan-head Housing Screws into their pre-drilled holes along the edges
of the MB-TP12/15 back box (FIG. 34) and secure them using a grounded Phillips-head
screwdriver.
4. Place the I/O connector plate back over the connector opening and align the connector locations.
5. Resecure the I/O connector plate (using a grounded Phillips-head screwdriver) and resecure the
Stereo Output nut on the Stereo Output jack.
FIG. 33 Location of the attachment screws on the NXD back box
Unscrew these four Housing Screws
DO NOT
these
DO NOT REMOVE
REMOVE
panel
securing
screws
these panel
securing screws
to remove the back box.
These make direct contact with the black
outer housing.
DO NOT REMOVE THE FOUR PANEL SECURING SCREWS. These screws secure
the LCD to the metallic casing underneath.