171
VG-Series Modero Touch Panels
Determine what is the available data rate for the network on which the encoder currently
resides. This information will determine what encoder profile can be used on the outgoing
media content. If the network can only handle a throughput of 4 Mbps from the encoder, it is
recommended that you use something less than or equal to the High Quality encoder profile.
Setting up a Modero Panel to Receive and Display a Stream
The MAX-CSE must first be prepared to stream to the target Modero panel prior to creating the
necessary TPDesign4 panel pages (later be uploaded to the panel).
Step 1: Obtaining the IP Address of the target panel
1.
Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 127).
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected
Setup page and display an on-screen keypad.
3. Enter 1988 into the Keypad’s password field and press Done when finished.
4. Press the System Settings button (located on the Protected Setup page) to open the System Settings
page and obtain the IP information from the IP Address field (FIG. 128).
FIG. 127 Setup page
FIG. 128 System Settings page
Connection Status
Red Connection Status icon -
Green Connection Status icon -
indicates no connection to a Master
indicates communication to a Master
Modero
IP Address
information