Fujitsu C122-E177-01EN Computer Hardware User Manual


 
MMB Web-UI (Web User Interface) Operations
Items
Description
On/ Off of the Location LED can be controlled by clicking [On], [Off] buttons.
Reset MMB Resets the MMB if this check box is checked.
When this check box is checked, [Switch Over to MMB] mentioned below cannot
be set.
Switch Over to MMB Switches the Active/Standby of the MMB if this check box is checked.
When this check box is checked, [Reset MMB] mentioned above cannot be set.
Remarks
This check box is displayed only, when two MMBs are mounted.
Enable/Disable MMB Controls Enable/ Disable of the MMB.
Because this item is a facility used for testing, it is not possible to usually set it.
Voltage
Sensor
Displays the Voltage sensor type.
P3.3VL
P1.5VL
P1.5VL_CPLD
P1.2VL
P1.0VL
P0.75VL
Voltage
Displays the current power voltage.
Threshold
Warning
(Low/High)
Lower and upper limits of the warning-level voltage.
Displays “ ”, when the threshold is not set.
Displays the power voltage in the last two decimal places.
Critical
(Low/High)
Lower and upper limits of the critical-level voltage.
Displays “ ”, when the threshold is not set.
Displays the power voltage in the last two decimal places.
TABLE 1.54 [MMB#x] Window button
Buttons
Description
On
Turns on the Location LED when the [On] button is clicked.
Off
Turns off the Location LED when the [Off] button is clicked
Apply
Click the [Apply] button to set the specified control information.
Cancel
Click the [Cancel] button to restore the original information and not set the specified information.
(1) Menu Operation
[System] – [MMB] – [MMB#x]
(2) Window Operations
Confirmation dialogue box is displayed. Specify the information which shows the change in MMB
status, click the [Apply] button. Sets the information which shows the change in MMB status.
[Message]
This section describes the messages to be displayed on this window.
Message Number
Message
I_00013
Setting completed.
I_00052
MMB switch processing has started.
I_00095
The standby MMB is rebooting now. Please wait several minutes.
E_00100
Failed to set the LED
E_00125
Failed to switch over to another MMB.
E_00125
Failed to change Enable/Disable status of the MMB.
E_00125
Failed to reset the MMB.
I_00213
%aa cannot be executed because the system is under maintenance.
I_00467
The reboot is done. Login after a while.
W_00413
Nothing is selected.