Fujitsu C122-E177-01EN Computer Hardware User Manual


 
MMB Web-UI (Web User Interface) Operations
Status
The state of a physical drive is displayed.
· Operational
· Available
· Failed
· Hot Spare
· Rebuilding
· SMART err
· Not-present
Vendor
The vendor of a physical drive is displayed.
Model
The model name of a physical drive is displayed.
Capacity
The capacity of a physical drive is displayed.
Logical Drives
Sensor#
The sensor number of a logical drive is displayed.
Status
The state of a logical drive is displayed.
RAID Level
The RAID level of a logical drive is displayed.
Physical Drives
assignment
The slot number of a physical drive that composes a logical drive is displayed.
Missing drives
Count
The number of physical drives missed to compose a logical drive at the RAID level is
displayed.
RAID Action Progress
Drive Type
The drive type that the RAID action is executed is displayed.
· Physical : Hardware RAID
· Logical : Software RAID
Slot#/Sensor#
Slot# from which the RAID action is executed is shown when Drive Type is Physical,
and Sensor# from which the RAID action is executed is shown when Drive Type is
Logical.
Action
The RAID action under execution is displayed.
· Rebuilding : It is shown for a physical drive to execute the rebuild of the RAID
drive.
· MDC Running : It is shown for a logical drive to execute MDC(Make Data
Consistent).
Progress
The progress rate of the RAID action under execution is displayed by the percentage.
Estimated time
remaining
(hh:mm:ss)
The remaining time that will be expected by the time the RAID action under execution is
completed is displayed.
Chipset
Chipset
·
OK
· Warning
· Failed
TPM
TPM
Displays the status of the TPM.
· OK
· Warning
· Failed
Notes
When the SB is ‘without TPM mode’, this field is not displayed.
Remark
The TPM is not displayed in the SB for China.